TEMPEST \ TR24-12B

Tempest TR24-12B

Nominal Voltage

12 V

Rated Capacity (20 hour rate)

24AH

Dimension

Total Height
(with terminals)

4.92 in

Height

4.92 in

Length

6.50 in

Width

6.93 in

Weight (Approx)

19.62 lbs

Capacity
(77oF/25oC)

20 hour rate (1.2A)

24AH

10 hour rate (2.23A)

22.3AH

5 hour rate (4.08A)

20.4AH

1 hour rate (14.4A)

14.4AH

15 min. rate (42A)

10.5AH

Internal Resistance

Fully Charged 77oF/25oC

10mW

Capacity Affected by Temperature
(77oF/25oC)

104°F (40°C)

102%

77°F (25°C)

100%

32°F (0°C)

85%

5°F (-15°C)

65%

Self Discharge
(77oF/25oC)

Capacity after 3 month storage

91%

Capacity after 6 month storage

82%

Capacity after 12 month storage

64%

Max. Discharge Current
(77oF/25oC)

360A (5S)

Terminal

Standard

F3

Optional

 

Charging (Constant Voltage)

Cycle

Initial Charging Current 4.8A (recommended)
14.9~14.9V/ 77°F (25°C)

Float

13.6~13.8V/77°F (25°C)

Cut-Off Voltage

30min

1 hour

2 hr

5 hr

12 hr

24 hr

1.60V

50.7

34.1

19.6

9.26

3.96

2.01

1.65V

50.0

33.4

19.2

9.26

3.96

2.01

1.70V

49.0

32.5

18.5

9.26

3.96

2.01

1.75V

48.2

31.8

18.1

9.20

3.96

2.01

1.80V

47.3

30.9

17.6

8.96

3.93

2.01

| Back |