TEMPEST\TR0.8-12

 

Tempest TR0.8-12

Nominal Voltage

12 V

Rated Capacity (20 hour rate)

0.8AH

Dimension

Total Height
(with terminals)

2.40 in

Height

2.40 in

Length

3.78 in

Width

0.98 in

Weight (Approx)

0.75 lbs

Capacity
(77oF/25oC)

20 hour rate (40mA)

0.8AH

10 hour rate (74mA)

0.74AH

5 hour rate (136mA)

0.68AH

1 hour rate (480mA)

0.48AH

15 min. rate (1.4A)

0.35AH

Internal Resistance

Fully Charged 77oF/25oC

160mW

Capacity Affected by Temperature
(77oF/25oC)

104°F (40°C)

102%

77°F (25°C)

100%

32°F (0°C)

85%

5°F (-15°C)

65%

Self Discharge
(77oF/25oC)

Capacity after 3 month storage

91%

Capacity after 6 month storage

82%

Capacity after 12 month storage

64%

Max. Discharge Current
(77oF/25oC)

12A (5S)

Terminal

Standard

SPECIAL

Optional

 

Charging (Constant Voltage)

Cycle

Initial Charging Current 160mA (recommended)
14.5~14.9V/ 77°F (25°C)

Float

13.6~13.8V/77°F (25°C)

Cut-Off Voltage

5min

10min

15min

30min

40min

60min

1.50V

6.3

4.2

3.2

2.0

1.6

1.1

1.65V

6.1

4.1

3.2

1.9

1.5

1.1

1.67V

6.0

4.0

3.1

1.9

1.5

1.1

1.70V

5.9

4.0

3.0

1.8

1.5

1.1

1.75V

5.8

3.9

3.0

1.8

1.4

1.0

| Back |