TEMPEST \ PRODUCTS \ TR SERIES

BC-1250 series :

4-stages mircoprocessor based system for charging and maintenance, for all types of lead-acid batteries, including sealed, AGM, GEL, VRLA, maintenance free, and flooded. 12 Volts / 6 Volts @ 1.25 Amp. UL Approved. Weight 3lbs.

 

4-stage progressive charging program by steps:

1.

Qualification: Ensure the battery status in safety prior to charging

2.

Constant Current Charging: Raises battery voltage to reach about 80% full

3.

Constant voltage Charging: Holds battery voltage at 80% and forces current to top off the battery.

4.

Float Maintenance: Maintain the fully charged battery at a proper working voltage

Specification:

 

Model No.

BC-12-1250

BC-06-1250

Ideal For

Suitable for wide range of Lead Acid Batteries for Motorcycles, ATVs and Personal Watercrafts

Output

12Vdc @ 1.25Amp

6Vdc @1.25Amp

AC Input

120V 60Hz

Power Consumption

33W

19.5W

Constant current mode

Forced current 1.25 Amp to reach at least 80% full

Constant voltage mode (Peak)

14.5V for 12V batteries

7.2V for 6V batteries

Defective Battery charging

This circuit monitors battery voltage, only after a designated time period, then it will switch to float mode

Absorption to Float Transition

 Charge Current drops: below 0.1 Amp if Absorption Charge Duration exceeds 6 hours, or if battery voltage does not reach Absorption Charge Level within 72 hours

Float / Maintenance Voltage

13.2 VDC = (2.2 vpc)

6.6 VDC = (2.2 vpc)

Operating Temperature

-20oC to 50oC

Packing and Shipping details :

Dimensions

3.60" X 3.25" X 4.20"

Net Weight

3lbs

Carton Size

330 mm x 405 mm x 280 mm (6 sets per carton)

Shipping Weight

3lbs

Enclosure

Powder Coated Aluminum Chassis

 

 Special Features:

 Short Circuit Protection:

YES

 Reverse Polarity Protection:

YES

 Spark Proof:

YES

 Temperature Compensation:

YES= -3.5mV/ °C/ Cell

NO

 Approval Agency Listings

UL Approved!, GS, CE

Back